Experimental Investigation of Condenser Performance in Freshwater Production from Seawater Desalination using Air-Conditioner Waste Heat

Ahmad Faiz Rahmatullah, Dan Mugisidi, Oktarina Heriyani, Rifky Rifky, Ahmad Rizal Dzikrillah, Genta Prastanadira, Salman Alfariz

Abstract


Freshwater scarcity remains a critical global issue driven by population growth, urbanisation, and climate change. Humidification–dehumidification (HDH) desalination has attracted increasing attention as a small-scale and energy-efficient technology because it can operate using low-grade thermal energy, including waste heat from air-conditioning systems. This study experimentally evaluated the performance of a fin-tube condenser integrated into an HDH seawater desalination system powered by air-conditioner waste heat. The experimental system consisted of an air-conditioning unit, an evaporation tank, a fin-tube condenser, a cooling-water circulation unit, and instruments for measuring temperature, relative humidity, airflow velocity, and condensate yield. Experiments were carried out over three consecutive days under comparable operating conditions. The results showed that the inlet humid-air temperature ranged from 43.71°C to 45.14°C and decreased to 23.96–25.87°C after passing through the condenser. The relative humidity increased from 46.81–48.74% at the condenser inlet to 99.27–99.99% at the outlet, indicating that the humid air approached a saturated condition after cooling. The airflow velocity decreased from 1.02 m/s at the inlet to 0.63 m/s at the outlet, suggesting increased contact time between humid air and the condenser surface. The calculated dew-point condition also confirmed that the cooling process supported condensation inside the condenser. The cooling-side heat transfer rate increased from 12,272.03 W to 13,494.33 W, while the condenser effectiveness ranged from 71% to 74%. The actual condensate effectiveness production varied from 3,185 g to 3,569 g, corresponding to a condensation effectiveness of 92–95%. These findings indicate that the fin-tube condenser provides effective heat removal, supports near-saturated outlet conditions, and enables stable condensate production in an HDH desalination process. The proposed system demonstrates the potential of utilising air-conditioner waste heat for sustainable freshwater production and energy-efficient small-scale desalination applications.

Keywords


Seawater Desalination; Humidification–Dehumidification; Fin-Tube Condenser; Air-Conditioner Waste Heat; Condensation Efficiency; Freshwater Production

Full Text:

PDF

References


Abed, K. N. (2023). The effect of location and shape of vortex generators on aerodynamic characteristics of a NACA 4415 airfoil. Al-Nahrain Journal for Engineering Sciences, 26(3), 198–204. https://doi.org/10.29194/NJES.26030198

Adegbola, A. A., Adeaga, O. A., Babalola, A. O., Oladejo, A. O., & Alabi, A. S. (2021). Improving the heat transfer rate of air conditioning condenser by material optimization. Journal of Energy Research and Reviews, 8(4), 39–50. https://doi.org/10.9734/JENRR/2021/v8i430219

Alenezi, A., & Alabaiadly, Y. (2025). Emerging technologies in water desalination: A review and future outlook. Energy Nexus, 17, 100373. https://doi.org/10.1016/j.nexus.2025.100373

Al-Obaidi, M. A., Rashid, F. L., Hashim, A. J., Al-Musawi, S. S., Almaamari, Q., & Mujtaba, I. M. (2025). A review on the impact of condenser technologies on solar still productivity. Sustainability, 17(23), 10786. https://doi.org/10.3390/su172310786

Assareh, E., Firoozzadeh, M., Zoghi, M., Zare, A., Ghazi, Y., & Shahin-Banna, A. (2024). Water desalination using waste heat recovery of thermal power plant in tropical climate; optimization by AI. Energy Conversion and Management: X, 24, 100731. https://doi.org/10.1016/j.ecmx.2024.100731

Heriyani, O., & Mugisidi, D. (2025). CFD simulation for optimizing the evaporation process in seawater desalination using exhaust heat from AC and vortex generators. Desalination and Water Treatment, 322, 101145. https://doi.org/10.1016/j.dwt.2025.101145

Krempaský, J., Havlík, J., & Dlouhý, T. (2022). Theoretical and experimental study of water vapour condensation with high content of non-condensable gas in a vertical tube. Acta Polytechnica, 62(3), 352–360. https://doi.org/10.14311/AP.2022.62.0352

Kumar, L., Soomro, J., Khoharo, H., & Assad, M. E. H. (2023). A comprehensive review of solar thermal desalination technologies for freshwater production. AIMS Energy, 11(2), 293–318. https://doi.org/10.3934/energy.2023016

Luberti, M., & Capocelli, M. (2023). Enhanced humidification–dehumidification (HDH) systems for sustainable water desalination. Energies, 16(17), 6352. https://doi.org/10.3390/en16176352

Luo, Y., Li, G., Bennett, N. S., Luo, Z., Munir, A., & Islam, M. S. (2025). Heat transfer enhancement in heat exchangers by longitudinal vortex generators: A review of numerical and experimental approaches. Energies, 18(11), 2896. https://doi.org/10.3390/en18112896

Mahmood, R. A., Ali, O. M., Al-Janabi, A., Al-Doori, G., & Noor, M. M. (2021). Review of mechanical vapour compression refrigeration system part 2: Performance challenge. International Journal of Applied Mechanics and Engineering, 26(3), 119–130. https://doi.org/10.2478/ijame-2021-0039

Mugisidi, D., & Heriyani, O. (2024). Improving the performance of a forced-flow desalination unit using a vortex generator. CFD Letters, 16(10), 81–93. https://doi.org/10.37934/cfdl.16.10.8193

Mugisidi, D., Fajar, A., Rifky, R., & Heriyani, O. (2022). Efisiensi termal dan efektivitas produksi kondensor pada solar still terpadu. Jurnal Teknosains, 12(1), 19–31. https://doi.org/10.22146/teknosains.70731

Mugisidi, D., Fajar, B., Syaiful, S., & Utomo, T. (2023). Solar still with an integrated conical condenser. CFD Letters, 15(8), 122–134. https://doi.org/10.37934/cfdl.15.8.122134

Mugisidi, D., Heriyani, O., Rifky, Widodo, Rahmani, A., & Khalid, A. (2026). Airflow-enhanced evaporation–condensation seawater desalination using residential air conditioner waste heat. Environmental Progress & Sustainable Energy, e70555. https://doi.org/10.1002/ep.70555

Nabil, I., Dawood, M. M. K., Mansour, T. M., Shehata, A. I., & Abdalla, A. M. (2025). Improved productivity of seawater desalination systems through humidification–dehumidification process integrated with renewable and fogging technologies in a lowest cost. Applied Water Science, 15, 115. https://doi.org/10.1007/s13201-025-02446-w

Nurkholid, N., Mugisidi, D., Widodo, W., Heriyani, O., & Sulistiono, I. (2025). Enhancing seawater desalination performance using a vortex generator in a modified window air conditioner. Jurnal Polimesin, 23(1), 38–42. https://doi.org/10.30811/jpl.v23i1.6110

Olufisayo, O. E., & Olanrewaju, O. (2024). A review of renewable energy powered seawater desalination treatment process for zero waste. Water, 16(19), 2804. https://doi.org/10.3390/w16192804

Orfi, J., Sherif, R., & AlFaleh, M. (2025). Conventional and emerging desalination technologies: Review and comparative study from a sustainability perspective. Water, 17(2), 279. https://doi.org/10.3390/w17020279

Poredoš, P., Petelin, N., Vidrih, B., Žel, T., Ma, Q., Wang, R., & Kitanovski, A. (2022). Condensation of water vapor from humid air inside vertical channels formed by flat plates. iScience, 25(1), 103565. https://doi.org/10.1016/j.isci.2021.103565

Romps, D. M. (2021). Accurate expressions for the dewpoint and frost point derived from the Rankine–Kirchhoff approximations. Journal of the Atmospheric Sciences, 78(7), 2113–2116. https://doi.org/10.1175/JAS-D-20-0301.1

Saini, P., Dhar, A., & Powar, S. (2023). Performance enhancement of fin and tube heat exchanger employing curved trapezoidal winglet vortex generator with circular punched holes. International Journal of Heat and Mass Transfer, 209, 124142. https://doi.org/10.1016/j.ijheatmasstransfer.2023.124142

Suhendar, A. D., Abdulah, A., & Azizah, R. L. (2022). Energy analysis in a vapor compression refrigeration system using R32 refrigerant. Mechanical Xplore, 3(2), 67–77.

Syaiful, Wahyuni, T., Yunianto, B., & Sinaga, N. (2021). Evaluation of vortex generators in the heat transfer improvement of airflow through an in-line heated tube arrangement. Fluids, 6(10), 344. https://doi.org/10.3390/fluids6100344

Zhang, G., & Wang, X. (2024). Seawater desalination system driven by sustainable energy: A comprehensive review. Energies, 17(22), 5706. https://doi.org/10.3390/en17225706




DOI: http://dx.doi.org/10.26737/var.v9i1.9376

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

Publisher:

Institute of Managing and Publishing of Scientific Journals, STKIP Singkawang

Address : STKIP Singkawang, Jalan STKIP - Kelurahan Naram, Singkawang, Kalimantan Barat, INDONESIA, 79251
No. Telp.   : +62562 420 0344
No. Fax.    : +62562 420 0584

VARIABEL

e-ISSN : 2599-3038

p-ISSN : 2599-302X

Editor in Chief Contact: [email protected] / [email protected] /Wa : +6285310307312

Publisher Contact: [email protected] / [email protected] / Wa: +6282142072788

Management Tools

     

VARIABEL IS INDEXED BY

           


Creative Commons License

Variabel is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.